3.2.9. Exciter Pause Period
Changes exciter pulse period setting. The parameter issued must be multiplied by five
to calculate the exciter pause timing in milliseconds. Supported are values between 4h
and FFh, equaling 20 ms to 1275 ms.
Write Command: K
Read Command: k
Write Command Parameters: xx<CR>, where xx is a hexadecimal value.
Readers Response:
wo/Command Prompt
7
w/Command Prompt
7
<CR><LF>
*K-xx<CR><LF>
<CR><LF>
*K-xx<CR><LF>
<LF>
>
3.2.10. FDX Delay Period
Changes FDX delay setting. The parameter issued must be multiplied by five to
calculate the FDX delay time in milliseconds. Supported are values between 1h and
8h, equaling 5 ms to 40 ms.
Write Command: U
Read Command: u
Write Command Parameters: xx<CR>, where xx is a hexadecimal value.
Readers Response:
wo/Command Prompt
7
w/Command Prompt
7
<CR><LF>
*U-xx<CR><LF>
<CR><LF>
*U-xx<CR><LF>
<LF>
>
7
See section 3.2.5. Serial ID-Code format settings.