Allflex AFX-100 Manuel d'utilisateur Page 48

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 47
Rev Australasia V2.3 12/04
48 48
3.2.7. Read Time
Sets read time for requested readings in seconds. Legal values range from one to nine
seconds!
Write Command: A
Read Command: a
Write Command Parameters: x<CR>, where x is a decimal value.
Readers Response:
wo/Command Prompt
6
w/Command Prompt
6
<CR><LF>
*A-x<CR><LF>
<CR><LF>
*A-x<CR><LF>
<LF>
>
3.2.8. Exciter Pulse Period
Changes exciter pulse period setting. The parameter issued must be multiplied by five
to calculate the exciter pulse timing in milliseconds. Supported are values between 3h
and 28h, equaling 15 ms to 200 ms.
Write Command: J
Read Command: j
Write Command Parameters: xx<CR>, where xx is a hexadecimal value.
Readers Response:
wo/Command Prompt
6
w/Command Prompt
6
<CR><LF>
*J-xx<CR><LF>
<CR><LF>
*J-xx<CR><LF>
<LF>
>
6
See section 3.2.5. Serial ID-Code format settings.